A57 BT HumidityLogging
下載
功能介紹
- IP54
- , -40℃
- , max. Logging64000setsData
- supports APPand and Data
- and design, convenient to use
- : 3.6V 2700mAh andsupportsUSB
- standardAccessories Accuracy Humidity, Humidity,. ( A57 BT)
- optional AccuracyNTCTemperature, ( A57 BT)
|
type |
A57 BT |
||
|
NTC |
(standardAccessories) |
||
|
TemperatureAccuracy |
0℃≤t≤60℃ |
±0.4℃ |
±0.3℃ |
|
-40℃≤t<0℃ |
±1℃ |
±0.5℃ |
|
|
60℃ |
|||
|
32℉≤t≤140℉ |
±0.8℉ |
±0.6℉ |
|
|
-40℉≤t<32℉ |
±2℉ |
±0.9℉ |
|
|
140℉ |
|||
|
HumidityAccuracy |
0%≤RH ≤90% |
\ |
±2.5%RH(25℃ ) |
|
90% |
\ |
±3.5%RH(25℃ ) |
|
|
Temperature/HumidityResolution |
0.1℃(0.1℉)/0.1%RH |
0.1℃ |
0.1℃(0.1℉)/0.1%RH |
|
Temperature Range |
-40℃~ 85℃(-40℉~ 185℉) |
||
|
Humidity |
0%~100%RH |
\ |
0%~100%RH |
|
Logging |
64000sets |
||
|
max. /min. / |
Yes |
||
|
LED |
Yes |
||
|
backlight |
Yes |
||
|
|
Yes |
||
|
|
Yes |
||
|
APP |
Yes (TempLink) |
||
|
|
Yes |
||
|
Recording Interval |
10s~ 24hours( /APP ) |
||
|
|
/ / approx. |
||
|
|
15s±2s( /APPconfigurable) |
||
|
USB |
USB Type-C |
||
|
USB |
supports(, ) |
||
|
type |
3.6V 2700mAh(ER14505) |
||
|
|
2 (, Recording Interval15min, 15s,, /backlight ) |
||
|
Logging |
or |
||
|
Humidity |
-40℃~+85℃,≤99%RH,non-condensing |
||
|
Temperature |
-40℃~+85℃( ) |
||
|
-40℃~+60℃( ER14505 ) |
|||
|
|
EMC:EN 61326-1:2021,ROHS |
||
|
|
IP54 |
||
|
Weight |
approx.110g |
||
|
Dimensions |
62x104x25 mm |
||
量測範圍
- NTC(standardAccessories)
- TemperatureAccuracy0℃≤t≤60℃|±0.4℃|±0.3℃
- -40℃≤t<0℃±1℃|±0.5℃
- 32℉≤t≤140℉±0.8℉|±0.6℉
- -40℉≤t<32℉±2℉|±0.9℉
- HumidityAccuracy0%≤RH ≤90%|\|±2.5%RH(25℃ )
- 90%\|±3.5%RH(25℃ )
- Temperature/HumidityResolution0.1℃(0.1℉)/0.1%RH|0.1℃|0.1℃(0.1℉)/0.1%RH
- Temperature Range-40℃~ 85℃(-40℉~ 185℉)
- Humidity0%~100%RH|\|0%~100%RH
- Logging64000sets
- max. /min. /√
- LED√
- backlight√
- Specification√
- Specification √
- APP√ (TempLink)
- Specification √
- Recording Interval10s~ 24hours( /APP )
- Specification / / approx.
- Specification 15s±2s( /APPconfigurable)
- USBUSB Type-C
- USB supports(, )
- type3.6V 2700mAh(ER14505)
- Specification 2 (, Recording Interval15min, 15s,, /backlight )
- Logging or
- Humidity -40℃~+85℃,≤99%RH,non-condensing
- Temperature-40℃~+85℃
- Specification EMC:EN 61326-1:2021,ROHS
- Specification IP54
- Weightapprox.110g
- Dimensions62x104x25 mm
量測功能
- 1IP54
- 2
- 3, -40℃
- 4, max. Logging64000setsData
- 5supports APPand and Data
- 6and design, convenient to use
- 8standardAccessories Accuracy Humidity, Humidity,. ( A57 BT)
- 9optional AccuracyNTCTemperature, ( A57 BT)
- Specification3.6V 2700mAh andsupportsUSB